ORA-12505, TNS:listener does not currently know of SID given in connect descriptor 해결

Max·2022년 7월 25일
0

ERROR

목록 보기
2/5
post-thumbnail

JDBC 연결을 하기 위해 데스트 코드 작성하고 실행을 했지만 오류
같은 문제 발생을 방지하기 위해 기록


java.lang.AssertionError: Listener refused the connection with the following error: ORA-12505, 
TNS:listener does not currently know of SID given in connect descriptor   	at org.junit.Assert.fail(Assert.java:88) 	at 
org.zerock.persistence.JDBCTests.testConnection(JDBCTests.java:33) 	at 
java.base/jdk.internal.reflect.NativeMethodAccessorImpl.invoke0(Native Method) 	at 
java.base/jdk.internal.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:62) 	at 
java.base/jdk.internal.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43) 	at 
java.base/java.lang.reflect.Method.invoke(Method.java:566) 	at org.junit.runners.model.FrameworkMethod$1.runReflectiveCall(FrameworkMethod.java:50) 	at 
org.junit.internal.runners.model.ReflectiveCallable.run(ReflectiveCallable.java:12) 	at org.junit.runners.model.FrameworkMethod.invokeExplosively(FrameworkMethod.java:47) 	at 
org.junit.internal.runners.statements.InvokeMethod.evaluate(InvokeMethod.java:17) 	at 
org.junit.runners.ParentRunner.runLeaf(ParentRunner.java:325) 	at org.junit.runners.BlockJUnit4ClassRunner.runChild(BlockJUnit4ClassRunner.java:78) 	at 
org.junit.runners.BlockJUnit4ClassRunner.runChild(BlockJUnit4ClassRunner.java:57) 	at org.junit.runners.ParentRunner$3.run(ParentRunner.java:290) 	at 
org.junit.runners.ParentRunner$1.schedule(ParentRunner.java:71) 	at org.junit.runners.ParentRunner.runChildren(ParentRunner.java:288) 	at 
org.junit.runners.ParentRunner.access$000(ParentRunner.java:58) 	at org.junit.runners.ParentRunner$2.evaluate(ParentRunner.java:268) 	at 
org.junit.runners.ParentRunner.run(ParentRunner.java:363) 	at org.eclipse.jdt.internal.junit4.runner.JUnit4TestReference.run(JUnit4TestReference.java:93) 	at 
org.eclipse.jdt.internal.junit.runner.TestExecution.run(TestExecution.java:40) 	at 
org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.runTests(RemoteTestRunner.java:529) 	at 
org.eclipse.jdt.internal.junit.runner.RemoteTestRunner.runTests(RemoteTestRunner.java:756) 	at org.eclipse.jdt.internal.junit.runner.RemoteTest


원인

ORA-12505, TNS:listener does not currently know of SID given in connect descriptor 는 SID가 맞지 않아 뜨는 에러다


해결

방법 1.

sql developer에서 SID명을 확인하고 JDBC 연결을 위한 코드에서 "jdbc:oracle:thin:@localhost:1521:EX";에 마지막 부분이 sql developer에 있는 SID명이랑 같은지 확인을 한다.

다르면 sql developer SID명과 같이 코드를 수정하고 실행해 본다.


방법 2.

C:\oraclexe\app\oracle\product\11.2.0\server\network\ADMIN 경로를 통해
tnsnames.ora를 메모장으로 열어본다

XE =
  (DESCRIPTION =
    (ADDRESS = (PROTOCOL = TCP)(HOST = --------)(PORT = 1521))
    (CONNECT_DATA =
      (SERVER = DEDICATED)
      (SERVICE_NAME = XE)
    )
  )

위와 같이 "SERVICE_NAME"에 값을 확인하고 코드 값도 확인하고 수정해 준다.




ref : https://wakestand.tistory.com/102